TRIOL AT24 line UB
Place an orderDistinctive benefits
Control type
Vector sensorless (open-loop) control
Motor parameters
Auto-tuning
Built-in
PID-controller
Multi-stage speed control
16 steps
4 parameter sets
Acceleration and deceleration time
About product
Simple, reliable and cost-effective solution
Variable Frequency Drive Triol AT24 line UB is a basic solution for common process tasks with simple installation, quick commissioning and easy operating. AT24 UB is simple, reliable and cost-effective solution to control pumps and HVAC systems. The integrated terminal allows making settings without additional equipment and service software.
Specifications
Input |
|
Input voltage, V |
3х380 / 3х480/ 3×690 (-15 % …+10 %) |
Input frequency, Hz |
50 / 60 (-5 %…+5 %) |
Output |
|
Output current, A |
1.2 … 110 |
Output frequency, Hz |
0.5…400 |
Frequency resolution, Hz |
0.1 |
Acceleration / deceleration time, s |
1 …36000 |
Overcurrent characteristics |
120 % of rated value for 60 sec |
Efficiency, % |
>97 |
Motor control |
|
Control methods |
V/f (volts-per-hertz) (5 reference point) sensorless vector control (open-loop) sensor vector control (close-loop) |
PWM frequency, kHz |
2…10 |
Speed range |
1:100 in open-loop system 1:1000 in closed-loop system |
Speed accuracy (static) |
±10% of motor nominal slip in open-loop system ±0.1 % of rated speed in close-loop system |
Torque accuracy |
±10% in open-loop system ± 5 % in close-loop system |
Braking |
By frequency Coasting Dynamic |
Acceleration / deceleration types |
S-curve, linear (3 reference points) |
Interface |
|
Terminal |
Integrated seven-segment |
Light alarm |
“Ready”; “Run”; “Control channel”, “Rotation” |
Push buttons |
“Start”; “Stop”; “Fast access “ |
Control signals |
|
Customer supply |
10 V DC, up to 30 mA 24 V DC, up to 150 mA |
Number of discrete inputs |
7 |
Discrete inputs |
2 Dl “Direction of rotation” by default 4 Dl programmable 1 Dl high speed pulse input |
Discrete inputs type |
24 V |
Number of relay outputs |
2 |
Relay outputs type |
250 V, 1 A |
Discrete output |
1 DO high speed or open collector |
Number of analog inputs |
2 |
Analog inputs |
1 Al 0…10 V by default 1 Al programmable 0…10 V or 0…5 mA or 4…20 mA |
Number of analog outputs |
2 |
Analog outputs |
Programmable 0…10 V or 0…5 mA or 4…20 mA |
Communication |
|
Physical Interface |
2 wire RS-485 for Modbus |
Communication protocols |
Modbus RTU |
Frame transmission |
19200 bps by default 1200, 2400, 4800, 9600,19200, 38400 bps |
Data format |
8 bits, 1 stop bit, no parity |
Number of addresses |
1…247 for Modbus |
Access |
Slave |
Protection |
|
Supply protections |
Phase loss |
Motor protections |
Overload Phase loss |
VFD protections |
Overload, Overheating, DC-link undervoltage, DC-link overvoltage, Power switch failure |
Insulation |
Galvanic isolation between power and user circuits |
Insulation resistance |
>1 MQ |
Configuration |
|
Braking IGBT-chopper |
Up to 15 kw: built-in From 18 kW: option, built-in |
Optional equipment |
|
Braking resistors |
Option, outdoor, by request |
Input line choke |
Option, outdoor, by request |
Input EMC filter (C2) |
Option, outdoor, by request |
Output dV/dt filter
|
Option, outdoor, by request |
Construction |
|
Protection degree of Enclosure |
IP21 |
Cabinet material |
Up to 7.5 kw: plastic From 11 kW: steel |
Cooling |
Forced air |
Noise level, @ 1 m, dB(A) |
<75 |
Installation |
Wall mounting |
Maintenance |
One-side |
Cable entry |
Bottom |
Operating conditions |
|
Operating conditions |
Indoor, no caustic and volatile air, no dust |
Operating temperature |
-10…+40 °C (-10…+104 F) |
Storage temperature |
-40…+50 °C (-40…+122 F) |
Relative humidity, % |
from 5 to 90 non condensing |
Altitude, m |
up to 1000 m – rated power above 1000 m – with reduced power |
Functions
- Start / stop / reverse of motor with set acceleration and deceleration rates
- Auto-tuning of motor parameters
- PID-controller
- 2-wire control
- 3-wire control
- Automatic restart
- Accelerated passing of resonant frequencies (2 ranges)
- Simple PLC and multi-step speed control with 16 steps and 4 acceleration / deceleration times
- Recording the last 3 reasons of failures