Variable Speed Drive AK06 TD

Triol AK06 line TD includes AK06 6-12pulses VSDs with NEMA enclosure for controlling various types of motors and pumps. UL certified VSDs that meet international standards are included in the line as well. AK06 TD is characterized by a high degree of protection and successfully operates in harsh climatic conditions.

  • switching on and off the electric motor;
  • motor operation in "manual" mode;
  • braking of the motor in the presence of turbine rotation with a subsequent start;
  • optimization mode for the current with the specified motor speed;
  • automatic change of the output frequency according to the specified program;
  • smooth acceleration and deceleration of ESM at a given rate;
  • reversal of the electric motor;
  • automatic activation of the electric motor with adjustable time delay at power supply;
  • automatic maintenance of the set value;
  • electric motor remote control, parameter monitoring, protection settings through Downhole Measuring System via RS-485 interface;
  • recording information on the causes of the SED switch-on and off, as well as recording the current parameters when working in the built-in non-volatile memory;
  • motor control from the immersion device (sensor);
  • continuous monitoring of power supply voltage three phases, disconnection or prohibition of the inclusion of ESM in the absence of one of the phases.

Parameters АК06- ММ- 6 pulse FPWM АК06- ММ- 6 pulse, 6 step АК06- ММ- 12 pulse FPWM AK06-MM- 12 pulse AK06 UL
Voltage, V 380/480 380/480 380/480 380/480 380/480
Frequency, Hz 50 ... 60 50 ... 60 50 ... 60 50 ... 60 50 ... 60
Efficiency, % 97 97 97 97 97
Overload capability 120% of the nominal value for 120 s 120% of the nominal value for 120 s 120% of the nominal value for 120 s 120% of the nominal value for 120 s 120% of the nominal value for 60 s
Rectification circuit diode-thyristor 6 pulse bridge rectification scheme diode-thyristor 12 pulse bridge rectification scheme diode-thyristor 12 pulse bridge rectification scheme
Analog inputs 2 2 2 2 2
Digital inputs of arbitrary polarity 2 2 2 2 2
Enclosure NEMA3R – NEMA4X NEMA3R – NEMA4X NEMA3R – NEMA4X NEMA3R – NEMA4X NEMA4
Operation temperature, ºС -40 + 60 -40 + 60 -40 + 60 -40 + 60 -40 + 60
Altitude characteristics up to 1000 m above sea level up to 1000 m above sea level up to 1000 m above sea level up to 1000 m above sea level up to 1000 m above sea level
Active harmonic filter optional optional optional optional optional
Active rectifier optional optional optional optional optional
Standards GOST 24607-88, GOST 26567-85, GOST 27.003-90, GOST R 27.403-2009, GOST 427-75, GOST 9.032-74, GOST 9.301-86, GOST 30804.6.2-2013, GOST 30804.6.4-2013, IEC 60146-1-1 Edition 4.0 2009-06, NEMA 250-2008 GOST 24607-88, GOST 26567-85, GOST 27.003-90, GOST R 27.403-2009, GOST 427-75, GOST 9.032-74, GOST 9.301-86, GOST 30804.6.2-2013, GOST 30804.6.4-2013, IEC 60146-1-1 Edition 4.0 2009-06, NEMA 250-2008 GOST 24607-88, GOST 26567-85, GOST 27.003-90, GOST R 27.403-2009, GOST 427-75, GOST 9.032-74, GOST 9.301-86, GOST 30804.6.2-2013, GOST 30804.6.4-2013, IEC 60146-1-1 Edition 4.0 2009-06, NEMA 250-2008 GOST 24607-88, GOST 26567-85, GOST 27.003-90, GOST R 27.403-2009, GOST 427-75, GOST 9.032-74, GOST 9.301-86, GOST 30804.6.2-2013, GOST 30804.6.4-2013, IEC 60146-1-1 Edition 4.0 2009-06, NEMA 250-2008 GOST 24607-88, GOST 26567-85, GOST 27.003-90, GOST R 27.403-2009, GOST 427-75, GOST 9.032-74, GOST 9.301-86, GOST 30804.6.2-2013, GOST 30804.6.4-2013, IEC 60146-1-1 Edition 4.0 2009-06, NEMA 250-2008, UL 61010-1
 